The FVC-1 provides an interface for standard control switches, such as the DXE-CC-8 or your
own arrangement to voltage-multiplexed antenna systems. This interface system
will provide the voltages required to remotely select up to four antennas (or
four directions) through receiving or low power transmitting feedlines. It
provides fuse-protected 0V, +12 Vdc, -12 Vdc, and 12 Vac. output voltages
through a panel mounted feedline connector. These voltages can be used to
provide four-direction switching of an antenna array either through the feedline
or on a single wire supplemental control line. Control is done using a standard
1 of 4, BCD or switch closure interface. The FVC-1 is recommended for use
with the DX Engineering
RFS-2P Remote Four-Square Antenna System , the RBS-1
Reversible Beverage Antenna System , and the RLS-2
Transfer Switch . The CC-8
Control Console can provide the 1 of 4 and BCD input used by the FVC-1 or
you can use your own switch. The FVC-1 also has two LED indicators, red
and green, which indicate the presence and polarity of the output control
voltage being used. They are directional indicators that can be read at a
convenient distance and can aid in troubleshooting. Features
- Safe, external 12V heavy duty power pack.
- Metal Housing – superior shielding, rugged, and easy mounting
- Convenient installation– mounts anywhere in your shack
- Rugged Control Connector – reliable solder-less connections
- Internal thermal reset fuse- full protection against accidental shorts
- Flexible logic input- BCD or standard one-of-four, high or low actuated
- Operation indicators- bright red and green LED indicators can be seen at a
distance
 DXE-FVC-1 Feedpoint Voltage Coupler Instructions (1.11M pdf)
The FVC-1 uses type “F” CATV connectors for antenna connections, and both standard phono and “F” connectors for radio connections. It has a removable 5-terminal no-solder connector for control connections
The FVC-1 outputs 0V, +12Vdc, -12Vdc, or 12 Vac on the ANT feedline connector and the OUT terminal of the 5 terminal control connector. An internal jumper selects external source voltages of 9-15 Vdc or a simple switch closure to ground to control the output voltages. The switch closure option allows you to use a low-current rotary switch near your receiver for convenient direction control.
There are two LED indicators on the FVC-1. The red LED illuminates when the output is a positive 12V, the green LED illuminates when the output is negative12V and they both illuminate when the output is 12VAC. Refer to the appropriate control tables. Failure of any LED to illuminate when the proper input is supplied indicates a problem.
All products manufactured by DX Engineering are warranted to be free from defects in material and workmanship for a period of one (1) year from date of shipment. DX Engineering's sole obligation under these warranties shall be to issue credit, repair, or replace any item or part thereof which is proved to be other than as warranted; no allowance shall be made for any labor charges of Buyer for replacement of parts, adjustments or repairs, or any other work, unless such charges are authorized in advance by DX Engineering.
If DX Engineering's products are claimed to be defective in material or workmanship, DX Engineering shall, upon prompt notice thereof, issue shipping instructions for return to DX Engineering (transportation-charges prepaid by Buyer). Every such claim for breach of these warranties shall be deemed to be waived by Buyer unless made in writing.
The above warranties shall not extend to any products or parts thereof which have been subjected to any misuse or neglect, damaged by accident, rendered defective by reason of improper installation, damaged from severe weather including floods, or abnormal environmental conditions such as prolonged exposure to corrosives or power surges, or by the performance of repairs or alterations outside of our plant, and shall not apply to any goods or parts thereof furnished by Buyer or acquired from others at Buyer's specifications. In addition, DX Engineering's warranties do not extend to other equipment and parts manufactured by others except to the extent of the original manufacturer's warranty to DX Engineering. The obligations under the foregoing warranties are limited to the precise terms thereof. These warranties provide exclusive remedies, expressly in lieu of all other remedies including claims for special or consequential damages.
SELLER NEITHER MAKES NOR ASSUMES ANY OTHER WARRANTY WHATSOEVER, WHETHER EXPRESS, STATUTORY, OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS, AND NO PERSON IS AUTHORIZED TO ASSUME FOR DX ENGINEERING ANY OBLIGATION OR LIABILITY NOT STRICTLY IN ACCORDANCE WITH THE FOREGOING.
| Part # |
Part Name |
Ship By |
Price |
Add to Cart |
| DXE-RFS-2P |
Receive Four Square Array Controller & Switch Package
|
Ship Today |
$ 389.95 |
|
| DXE-RLS-2 |
Two Port Receive Antenna Switch
|
Ship Today |
$ 79.95 |
|
| DXE-CC-8 |
Antenna Switch 8 port Control Console Only
|
Ship Today |
$ 159.95 |
|

|