DX Engineering PRO-STACK Broadband Antenna Phasing Systems DXE-PS-2B-P

Write the First Review

Part Number: DXE-PS-2B-P

$895.98

PRO-STACK 2 Two Antenna Phasing System, 2-port, 5 kW, 160-10 meters, Relay Unit w/EC-PS2 Control Console, 4-cond., 12 Vdc, Kit
See More Specifications

DX Engineering PRO-STACK Broadband Antenna Phasing Systems DXE-PS-2B-P

DX Engineering PRO-STACK Broadband Antenna Phasing Systems DXE-PS-2B-P

DXE-PS-2B-P

Not Yet Reviewed

Part Number: DXE-PS-2B-P

Estimated Ship Date: Today

$895.98

Estimated Ship Date: Today Would you rather pick it up?

Required Parts

Kit/Combo Contents

Click here for more information about DX Engineering DXE-EC-PS2 - DX Engineering PRO-STACK 2 Control Consoles

DX Engineering DXE-EC-PS2 - DX Engineering PRO-STACK 2 Control Consoles

Control Console for PS-2B PRO-STACK 2, Manual Rotary Switch, Position LEDs, Internal Control Cable Termnals, 2.1mm 13.8 Vdc, Each

Kit Item Quantity: 1

Click here for more information about DX Engineering DXE-PS-2B - DX Engineering PRO-STACK Broadband Antenna Phasing Switches

DX Engineering DXE-PS-2B - DX Engineering PRO-STACK Broadband Antenna Phasing Switches

PRO-STACK 2 Two Antenna Phasing Relay Unit, 2-port, 5 kW, 160-10 meters, SO-239, Each

Kit Item Quantity: 1

Overview

Brand:
Manufacturer's Part Number:
DXE-PS-2B-P
Part Type:
Product Line:
DXE Part Number:
DXE-PS-2B-P
Stacking Switch Type:
2-port
Power Handling:
5 kW
Out-Of-Phase Selection:
Yes
Stacking Switch Control Wire Connection:
External
Control Wire Required:
4-conductor
Stacking Switch Band Range:
160-10 meters
Matched 50-ohm Coax Cables Required:
Yes
RF Connector Type:
UHF female, SO-239
Stacking Switch Width (in.):
10.375 in.
Stacking Switch Height (in.):
4.375 in.
Stacking Switch Depth (in.):
9.875 in.
Stacking Switch Weight:
9.10 lbs.
Control Console Width (in.):
6.38
Control Console Height (in.):
2.38
Control Console Depth (in.):
5.00
Control Console Weight:
1.30 lbs.
Quantity:
Sold as a set.

DX Engineering PRO-STACK Broadband Antenna Phasing Systems

DX Engineering PRO-STACK Broadband Antenna Phasing Systems are designed to combine two identical Yagi or log periodic beams, or three quarter-wave vertical antennas, into a phased array for enhanced directional pattern selections and dramatically improved HF operations.

There is no need for special coaxial delay lines with the DX Engineering PRO-STACK systems. Just connect your antennas to the system relay unit with equal-length 50-ohm coaxial cable assemblies. The PRO-STACK switch relay units are available with high-quality PTFE-silver plated SO-239, UHF female connectors. The matching PRO-STACK Control Console operates the system with a 1-of-3 source voltage control format at 12-15V DC with a user supplied four conductor control cable to achieve four different antenna phasing selections.

PRO-STACK Broadband Antenna Phasing Systems operate across the 160 to 10 meter range. They have two antenna ports that can be used for any application requiring the four basic selections:
1. BIP - Both antenna ports In-Phase
2. BOP - Both antenna ports Out-of-Phase
3. BOTTOM - Antenna port 1 only
4. TOP - Antenna port 2 only.
The unpowered default is 1 - Both ports In-Phase. Impedance matching is automatic in the PRO-STACK even when any antenna port is disconnected.

Generally, stacked Yagi antennas are separated vertically with greater than one half wavelength free space. Since the DX Engineering PRO-STACK Antenna Phasing Systems are broadband, they may be easily adapted to larger arrays. For example, four stacked Yagis may be combined by creating two sets of PRO-STACKS, with a third DX Engineering PRO-STACK to combine the first two.

PRO-STACK systems may also be used to feed quarter-wave resonant vertical antennas for a high-gain, 4-pattern array. This arrangement requires three verticals, with the center #2 passive antenna element directly grounded to the system ground radial system at all times, while elements #1 and #3 are then fed in various phase relationships by the PRO-STACK.

Details are in the complete PRO-STACK PS-2B Instruction Manual linked here in "Documentation" tab. The full- color printed manual is included with the system relay unit. PRO-STACK Broadband Antenna Phasing Systems are available as separate Relay Units for operators who have automated BCD switching devices, and as packaged systems with Relay Unit and matching manual Control Console.

Features of the DX Engineering PRO-STACK Broadband Antenna Phasing Systems include:

* Power handling up to 5 kW
* Broadband coverage on 160-10 meters
* High impact shielded weatherproof housing
* High-RF tolerant, silver-PTFE SO-239 (UHF female) connectors
* Proven DX Engineering RF relays for high performance
* Safe 12V relay operation
* DC-powered control console allows battery or solar emergency operation
* MOV surge protection on control lines
* External, removable control line connector
* RoHS-compliant assembly

Dominate the airwaves with DX Engineering PRO-STACK Broadband Antenna Phasing Systems.

* Important Note regarding DX Engineering Protection Plans and Kit Combo Contents

NOTE: Protection plans cannot be purchased for combination packages or on applicable devices after shipment.

DX Engineering Combination Kits and Packages are designed to help you easily visualize and order the right items for your specific needs. However, we encourage you to contact our experienced Technical Sales Team for assistance. We can help adjust the kit contents, suggest substitutions based on stock availability, and offer DXE Protection Plans for radios and devices when applicable.

Contact us for Expert assistance and make informed purchasing decisions with our guidance.


Documentation

 Loading...

Applications

 Loading...
 Loading...

Reviews Write a Review

Some parts are not legal for use in California or other states with similar laws / regulations

Modal Header

Call To Order

This is a custom order part. You can order this part by Contacting Us.

CA Warning Icon

Cancer and Reproductive Harm.

Email this page