SOTAbeams Antenna Center and 4:1 Transformers ACBA-102

Write the First Review

Part Number: SBM-ACBA-102

...Loading

Insulator-Balun, Antenna Center with 4:1 Matching Transformer, BNC female, 125W, Assembled, Each
See More Specifications

SOTAbeams Antenna Center and 4:1 Transformers ACBA-102

SOTAbeams Antenna Center and 4:1 Transformers ACBA-102

SBM-ACBA-102

Not Yet Reviewed

Part Number: SBM-ACBA-102

Estimated Ship Date: Apr 26, 2027

...Loading

Estimated Ship Date: Apr 26, 2027 Would you rather pick it up?

Overview

Brand:
Manufacturer's Part Number:
ACBA-102
Part Type:
Product Line:
DXE Part Number:
SBM-ACBA-102
Item Number:
6508564
Wire Antenna Component Type:
Center insulator
Feedline Connection Type:
BNC female
Center Insulator Hanging Hole:
Yes
Adapts to Baluns:
No
Cable Strain Relief Included:
Yes
Quantity:
Sold individually.
Notes:
Includes built-in antenna wire and coax strain relief mounting holes

SOTAbeams Antenna Center and 4:1 Transformers

SOTAbeams Antenna Center and 4:1 Transformers are a very handy feed point for a low-power lightweight portable HF doublet antenna project. Available as a kit (SBM- ACBA-101) or already built (SBM-ACBA-102). These are very versatile dipole center insulators that include these outstanding features:

• Coaxial Cable Strain-Relief Built In
• BNC female Connector
• Water-Resistant Construction with Integral UV Resistant Cover
• Antenna Wire Strain-Relief Built-in
• Binding Posts for Antenna Wire Connections
• Mounting Holes for Center Support Rope
• Lightweight – 3.1 oz. (88g)
• High Performance by Design - Flat Response from 3-30MHz
• Loss: < 0.2dB @ 14MHz
• Matched SWR < 1.15:1 1.8-30MHz (< 1.50:1 0.5-60MHz)
• Power Rating: 125W SSB-CW; 30W Digital

The SOTAbeams Antenna Center and 4:1 Transformers are useful for pre-matching higher impedance antenna systems such as doublets and folded dipoles to bring the SWR into the matching range of internal antenna tuners. In that application, the length of the feeder between the transformer and the tuner must be kept to about 6 ft. These Antenna Centers have a 4:1 matching transformer that is sometimes referred to as a balun. This isn't a choke, so strictly speaking it's not a choke balun, but it's typically referred to as a voltage balun.

This transformer is designed with a lip that can be sealed using a silicone sealant if required for use in more permanent installations. We do not supply the Balun sealed as this allows users to gain access to the enclosure and allow any buildup of moisture to drain away.

Note: Whenever the DX Engineering "Documentation" tab is available, please look at the associated files for additional product information.

 Loading...

Reviews Write a Review

Some parts are not legal for use in California or other states with similar laws / regulations

Modal Header

Call To Order

This is a custom order part. You can order this part by Contacting Us.

CA Warning Icon

Cancer and Reproductive Harm -- www.P65Warnings.ca.gov

Email this page