Selected Filters


Grounding and Lightning Protection

Grounding & Lightning Protection

Availability


Grounding & Lightning Protection

Protect your equipment from lightning damage with grounding and lightning protection from DX Engineering. We’re your complete source for grounding and lightning protection...

Protect your equipment from lightning damage with grounding and lightning protection from DX Engineering. We’re your complete source for grounding and lightning protection components, including coaxial lightning protectors, coax shield grounding kits, copper grounding straps, grounding plates and clamps, tinned copper braid, strap-to-tower leg grounding clamps, wire-to-ground rod clamps, and more. Find everything you need to build a complete, single-point grounding system to protect your entire installation. Lightning can disable your entire operation in a flash. Shop DX Engineering for grounding and lightning protection!

Protect your equipment from lightning damage with grounding and lightning protection from DX Engineering. We’re your complete source for grounding and lightning protection components, including coaxial lightning protectors, coax shield grounding kits, copper grounding straps, grounding plates and clamps, tinned copper braid, strap-to-tower leg grounding clamps, wire-to-ground rod clamps, and more. Find everything you need to build a complete, single-point grounding system to protect your entire installation. Lightning can disable your entire operation in a flash. Shop DX Engineering for grounding and lightning protection!

Part Groups

Results 1 - 5 of 5

DX Engineering 75 ohm Coaxial Lightning Surge Protectors

DX Engineering 75 ohm Coaxial Lightning Surge Protectors feature a unique design that is impedance-matched to 75 ohms and are virtually transparent to all analog or digital bi-directional signals from DC to 1.0 GHz. Manufactured by Tii Network Technologies for DX Engineering, their patented proprietary coaxial gas tube surge protectors are equipped with an integral failshort mechanism for a power-cross condition, which shunts both the coaxial cables' center conductor and sheath for a common path to ground. The dc breakdown voltage of the protector provides superior protection against transient surges, and yet is compatible with network-powered applications. They may also be used in 75-ohm receive systems up to 1.0 GHz. The protection element is designed to reset after each over-voltage event and the metallic housing of the coaxial lightning surge protectors provides necessary EMI shielding. When properly connected, DX Engineering Coaxial Lightning Surge Protectors are environmentally sealed (15 psi) to prevent the ingress of moisture and humidity encountered in broadband pedestals, vaults and stand-alone receive antenna applications. Full 360 degree Type F connectors provide superior RF performance and tighter connections.

5.0 out of 5 stars ( 9 )

$39.99

Paradan Radio Dual Antenna Disconnectors

Paradan Radio Dual Antenna Disconnectors reduce the chance of station damage from lightning pulses. The Dual Antenna Disconnector automatically disconnects and isolates any radio equipped with two antenna ports—and it grounds both antenna SO-239 coaxial connectors. The two radio SO-239 connectors may also be used for two separate transceivers or receivers. The Dual Antenna Disconnector is excellent for protecting remote stations from lightning pulse damage. The Dual Antenna Disconnector prevents static-discharge, surges, and lightning-pulse effects from damaging your radio and associated equipment. When the transceiver is turned OFF, both antenna coax center conductors and shields are shorted together and grounded—and both coax center conductors and coax shields are disconnected from the radio. When the transceiver is powered ON, the Disconnector re-connects both coaxial cables for normal operating. Power for the Disconnector can be supplied by either the transceiver's auxiliary DC power output or by the station power supply that is turned off when not operating. For stations where the power supply is always left on, the Radio ON Sensor unit tells the Disconnector to reconnect coaxial cable when the radio is turned on. For correct operation the Dual Antenna Disconnector requires a good earth ground. The unit is supplied with a ground wire ring terminal, four wire splice connectors, and a Powerpole® connector pair. Paradan Radio Dual Antenna Disconnector Specifications: * Power Handling: Over 1.5 kW on each circuit * Insertion Loss: Less than 0.05 dB below 29 MHz; 0.4 dB at 54 MHz; 1 dB at 144 MHz * Relay Operating Voltage: 10-18 V dc * Current: 120 mA at 13.8 V, when turned ON to connect antennas * LED: Illuminates green when relays connect the antennas for operating * Relays: Four relays with 15 amp contacts each, protected for reverse spikes * Case: Grounded to Antenna connectors and isolated from Radio coaxial connectors * Control Wire: 6 ft., two-conductor AWG 18 with RCA phono plug * Control Input: Diode protected against reverse polarity; RF filtered * Active Lightning Protection: Gas Discharge Tube on both Antenna inputs * Case Ground Stud: 1/4 in. (1/4-20) with washers, lock washer and nut * Case: Diecast aluminum, black paint, white print, water resistant * Size: 6 in. x 3.8 in. x 2.2 in., mounting tabs with 4 holes spaced at 5.25 in. and 2.50 in. on-center * Weight: 1 lb. 10 oz. ® Registered trademark of Anderson Power Products

4.68 out of 5 stars ( 19 )

$190.99

DX Engineering Ladder Line Surge Protector

Built by popular demand, the DX Engineering Ladder Line Surge Protector is ready to be placed in line with your balanced feedline antenna system! For many years, hams have asked us for a surge protector for use with their 300 ohm and 450 ohm ladder line fed antennas. Decades ago automotive spark plugs or arc gaps were used for shunting lightning pulses from balanced feeders to ground. But, you never really knew if they were going to work, if they really were continuing to work or if they were affecting the tuning. Here is the modern approach to providing surge protection for ladder line fed antennas. Made with components similar to those used in coaxial protectors, the DXE-LLSP uses much larger capacitors, resistors and gas discharge tubes on each leg of the ladder line to offer excellent surge protection capabilities at high SWR. These components are rated to handle 5 kW, so this protector will easily handle well over legal limit RF power at the high standing wave ratios expected on balanced line. Plus, the Ladder Line Surge Protector bleeds off the static charge that is collected on your antenna from wind driven sand, rain and snow! The DXE-LLSP Ladder Line Surge Protector is built to sustain multiple minor surges. As with any surge protector, there is no guarantee that a direct hit from lightning will be stopped. A replacement parts kit is also available to refurbish your pulse damaged protector: DXE-LLSP-RP Features of the DX Engineering Ladder Line Surge Protector: • Standard size NEMA enclosure; 4 x 4 x 2 in. nominal box dimensions; mounting tab holes on centers: 4.625 x 2.125 in. • Works with 450 ohm or 300 ohm Ladder Line and 600 ohm open-wire feeder • Internal Gas Discharge Tubes, Capacitors and Resistors • Can withstand multiple minor surges and shunts them to ground • Bleeds off static charge collected from wind driven snow, rain and sand • Weep holes allow any buildup of internal moisture to drain out • Handles well over legal limit at high SWR as expected on balanced line NOTE: The DXE-LLSP is an RF only device that does not carry DC voltage. Therefore it cannot be tested with a multimeter. It must be tested with an analyzer and a 300 ohm resistor, or by connecting an antenna feedline. If there is infinite SWR or no receive, the components have been damaged by lightning pulse energy and need to be replaced with the DXE-LLSP-RP Ladder Line Surge Protector Replacement Parts Kit. Order the DX Engineering Ladder Line Surge Protector for your balanced feedline antenna system today!

4.84 out of 5 stars ( 19 )

$85.99

On Sale

DX Engineering Radio RF Ground Plane Kits

DX Engineering Radio RF Ground Plane Kits provide an effective method of reducing stray RF pickup by equipment and interconnecting cables. Used under and connected to radio equipment, these 1/16 inch thick, pre-drilled aluminum or copper sheets create an RF reference plane that is also connected to the existing grounding bus. As described in the ARRL's "Grounding and Bonding for the Radio Amateur 2nd Edition" by H. Ward Silver, N0AX; a large surface area of metal improves upon the single conductor grounding buss by equalizing the RF E-field (electric field) around equipment and attached cables. This reduces voltage differences between pieces of equipment and the associated currents that cause RF interference to transceivers, microphones and accessories. The reduction in RF interference improves both transmitted and received signal quality. Radio RF Ground Plane Kits are available in 12 versions; three sizes of aluminum or copper plate with hardware and the same three sizes of aluminum or copper plates with companion mounting boards made of 1/2 inch thick Medium Density Fiberboard (MDF), with hardware. All kits are intended for indoor use only. As used by top contesters and DXers alike, a flat metal sheet placed under equipment, along with physically short grounding braids, wires and interconnection cables can significantly reduce the RF voltage differences between cables and equipment. The chance of RF trouble in your equipment is reduced by installing DX Engineering Radio RF Ground Plane Kits in your station.

5.0 out of 5 stars ( 16 )

$51.99

—

$235.99


$41.59

—

$188.79

On Sale

DX Engineering's Aluminum Radio RF Ground Plane Kits

DX Engineering's Aluminum Radio RF Ground Plane Kits provide an effective method of reducing stray RF pickup by equipment and interconnecting cables. Used under and in back of equipment, this 1/16 inch thick, pre-drilled aluminum sheet creates an RF reference plane that is typically connected to the existing grounding bus, and provides an economical alternative to a copper sheet. As described in the ARRL book "Grounding and Bonding for the Radio Amateur, 2nd Edition" by H. Ward Silver, N0AX; a large surface area of metal improves upon the single conductor grounding buss by equalizing the RF E-field (electric field) around equipment and attached cables. This reduces voltage differences between pieces of equipment and the associated currents that cause RF interference to transceivers, microphones and accessories. The reduction in RF interference improves both transmitted and received signal quality. Radio RF Ground Plane Kits are available in 12 versions; three sizes of copper or aluminum plate with hardware and the same three sizes of copper or aluminum plates with companion mounting boards made of Medium Density Fiberboard (MDF), with hardware. All kits are intended for indoor use only. As used by top contesters and DXers alike, a flat metal sheet placed under equipment, along with physically short grounding braids, wires and interconnection cables can significantly reduce the RF voltage differences between cables and equipment. The chance of RF trouble in your equipment is reduced by installing DX Engineering Aluminum Radio RF Ground Plane Kits in your station.

Not Yet Reviewed

$71.99


$57.59

  • 1
  • Page 1 of 1