Filters
Chelegance NANOVNA-F V2 3 GHz Mini Vector Network Analyzer
6 Customer Reviews
Specifications:
-Frequency range: 50 kHz - 3GHz
-S11 dynamic range: 50dB (50 kHz -
Specifications:
-Frequency range: 50 kHz - 3GHz
-S11 dynamic range: 50dB (50 kHz - 1.5 GHz), 40dB (1.5 GHz – 3 GHz)
-S21 dynamic range: 70dB (50 kHz - 1.5 GHz), 60dB (1.5 GHz - 3 GHz)
-RF output power: -9dBm
-Frequency tolerance: 0.5ppm
-Screen: 4.3 in. IPS LCD, 800x480 pixel, RTP touchpad
-Operation via touch screen or 3 side buttons
-Battery: 3.7V Li-Po, 5000mAh
-Enclosure type: Aluminum
-Enclosure Dimensions (WHD): 4.921 x 2.953 x 0.787 in. (125mm x 75mm x 20mm)
-RF port connector: SMA female
-Sweep points: 101
-Calibration result storage: 5
-Calibration result interpolating supported
-Traces: 4
-Markers: 4
-Measures: S-parameter, VSWR, smith chart, phase, polar, etc.
-Mark table can be moved up and down
-Firmware upgrade via U-disk with type-c cable
-USB power output: 5V/1A
-Compatible with NanoVNA-saver, support screenshot
Parts Included:
-NanoVNA-F V2 x1
-20cm SMA-JJ RG405 cable x2
-Calibration kit: SMA OPEN/SHORT/50 ohm LOAD
-SMA-KK adapter x1
-SMA-JJ adapter x1
-SMA-JKW adapter x1
-USB Type-C cable x1
-Stylus x1
Supporting Resources:
-User Manual & Quick Starter Guide
-[LATEST]NanoVNA-F V2 Portable Vector Network Analyzer User Guide V2.0.pdf (https://chelegance.com/wp-content/uploads/2021/10/CHELEGANCE_NanoVNA-F-V2-Portable-Vector-Network-Analyzer-User-Guide-V2.0..pdf)
-[LATEST]NanoVNA-F V2 Quick Start Guide – for firmware v0.3.0.pdf (https://groups.io/g/nanovna-f-v2/files/NanoVNA-F%20V2%20Quick%20Start%20Guide%20-%20for%20firmware%20v0.3.0.pdf)
Firmware:
-[LATEST]NanoVNA-F_V2_App_v0.3.0.zip (https://groups.io/g/nanovna-f-v2/files/Firmware/NanoVNA-F_V2_App_v0.3.0.zip)
-Download previous versions here (https://groups.io/g/nanovna-f-v2/files/Firmware)
Desktop Software:
-[LATEST]NanoVNA-Saver-0.3.8 (https://chelegance.com/wp-content/uploads/2021/10/Nanovna-Saver-0.3.8.exe)
Note: If the current firmware version of your NanoVNA-F V2 device is lower than v0.2.0, please upgrade to v0.2.0 first, and then upgrade to v0.3.0.
The new firmware v0.3.0 has the following features:
1. Menu style optimization; New menu UI style; New keyboard UI style: bigger buttons for avoiding typing error; Change the ordinate to 10 grids;
2. Optimized menu structure for more convenient operation;
3. Improved the measurement noise of high frequency;
4. Allow the reference position to be set to negative value;
5. Fixed known bugs.
Mini Vector Network Analyzer, 50 kHz - 3 GHz, 4.3 in. IPS LCD Touch Screen, Metal Enclosure, 5000mAh Li-Po Battery, SMA Connectors, Each
Part Number: NCE-NANOVNA-F-V2
Cannot be shipped Internationally
Cannot be shipped Internationally