Availability
Alpha Delta UHF Connector Coaxial Cable Surge Protectors
Alpha Delta UHF Connector Coaxial Cable Surge Protectors have SO-239 connectors and are rated for 200 or 2,000 watts at frequencies up to 500 MHz. They are not DC-blocked, so they will pass control voltages in applications requiring the coaxial cable to carry both RF and DC voltage. They may be easily mounted for the most effective grounding with a 1/4-20 bolt or stud (depending on model) in a single hole or as a bulkhead-mount through the grounding panel. In a study under the auspices of the U.S. Dept. of Energy, utilizing the satellite FORTE launched in 1997 carrying VHF lightning discharge sensors, it was determined that there can be damaging lightning energy emissions throughout the 30 through 300 MHz VHF spectrum. Before FORTE, it was thought that most lightning energy emissions were primarily in the VLF range. Therefore, the damage threat can be anywhere from VLF through VHF. Through the careful design of the Alpha Delta Arc-Plug® gas tube module and precision, constant impedance through-line allowing proper firing characteristics, these devices are designed to provide effective protection throughout this entire spectrum. Other surge protector designs may only utilize simple VLF filters with no gas tube backup. Additional features include: * Excellent broadband performance from DC through 500 MHz, compared to the narrow-band DC-blocked or stub designs. * Innovative impedance compensated through-line cavity design allows control voltages to pass through the device, instead of the "wire-around" requirement of DC-blocked designs. This design allows "in-circuit" cable sweeps. * Innovative, fast-acting gas tube replaceable Arc-Plug® module can be removed and replaced in the field in about one minute with no tools required, and without having to remove the protector from the circuit. The "O" ring sealed knurled knob does the trick! * The Arc-Plug® modules and connectors are "O" ring sealed for complete weatherproofing. * Effective performance. Due to the carefully designed reactance-compensated, through-line cavity and Arc-Plug® module placement, customer and government test approvals show this design is as good as, or better than, DC-blocked designs. Lightning surges do lots of damage annually. Protect your equipment from surges with Alpha Delta UHF Connector Coaxial Cable Surge Protectors from DX Engineering!
( 116 )
$69.99
—
$79.99
Alpha Delta N Connector Coaxial Cable Surge Protectors
Alpha Delta N Connector Coaxial Surge Protectors are rated for 200 or 2,000 watts at frequencies up to 3 GHz. They are not DC-blocked, so they will pass control voltages in applications requiring the coaxial cable to carry both RF and DC voltage. They can be easily mounted for the most effective grounding with their 1/4-20 in. stud in a single hole or as a bulkhead through the grounding panel. In a study under the auspices of the U.S. Dept. of Energy, utilizing the satellite FORTE launched in 1997 carrying VHF lightning discharge sensors, it was determined that there can be damaging lightning energy emissions throughout the 30 through 300 MHz VHF spectrum. Before FORTE, it was thought that most lightning energy emissions were primarily in the VLF range. Therefore, the damage threat can be anywhere from VLF through VHF. Through the careful design of the Alpha Delta Arc-Plug® gas tube module and precision, constant impedance through-line allowing proper firing characteristics, these devices are designed to provide effective protection throughout this entire spectrum. Other surge protector designs may only utilize simple VLF filters with no gas tube backup. Additional features include: * Excellent broadband performance from DC through 3 GHz, compared to the narrow-band DC-blocked or stub designs. Typical dB loss: 0.1@ 1 GHz; 0.2@ 2 GHz; and 0.5@ 3 GHz. * Innovative impedance-compensated, through-line cavity design allows control voltages to pass through the devices, instead of the "wire-around" requirement of DC-blocked designs. This design allows "in-circuit" cable sweeps. * Innovative, fast-acting gas tube replaceable Arc-Plug® module can be removed and replaced in the field in about one minute with no tools required, and without having to remove the protector from the circuit. The "O" ring sealed knurled knob does the trick! * The Arc-Plug® module and connectors are "O" ring sealed for complete weatherproofing. * Effective performance. Due to the carefully designed reactance-compensated, through-line cavity and Arc-Plug® module placement, customer and government test approvals show this design is as good as, or better than, DC-blocked designs.
( 22 )
$79.99
—
$99.99
Alpha Delta Surge Protector Replacement Arc-Plug® Cartridges
After hundreds of protective firings of the Arc-Plug® cartridges or after a catastrophic surge, the Arc-Plug® cartridges may fail, requiring replacement. Alpha Delta Surge Protector Replacement Arc-Plug® Cartridges are designed to get you back up and running in no time. Failure will be apparent due to the fact that they fail in a shorted or "fail-safe" mode, so as not to leave the equipment unprotected. Simply unscrew the failed Arc-Plug® cartridge by gripping the knurled surface and turning counter-clockwise. Make sure that the new Arc-Plug® Cartridge O-ring is fully seated into the body of the surge protector and you're back on the air! Protect your gear with renewable surge protection. Order Alpha Delta Surge Protector Replacement Arc-Plug® Cartridges and your Alpha Delta surge protectors from DX Engineering!
( 29 )
$15.99
Alpha Delta F Connector Coaxial Cable Surge Protectors
Alpha Delta F Connector Coaxial Surge Protectors are rated for 200 or 2,000 watts at frequencies up to 3 GHz. They are not DC-blocked, so they will pass control and power voltages in applications requiring the coaxial cable to carry both RF and DC voltage. They can be easily mounted for the most effective grounding with their 1/4-20 in. stud in a single hole, or as a bulkhead through the grounding panel. In a study under the auspices of the U.S. Dept. of Energy, utilizing the satellite FORTE launched in 1997 carrying VHF lightning discharge sensors, it was determined that there can be damaging lightning energy emissions throughout the 30 through 300 MHz VHF spectrum. Before FORTE, it was thought that most lightning energy emissions were primarily in the VLF range. Therefore, the damage threat can be anywhere from VLF through VHF. Through the careful design of the Alpha Delta Arc-Plug® gas tube module and precision, constant impedance through-line allowing proper firing characteristics, these devices are designed to provide effective protection throughout this entire spectrum. Other surge protector designs may only utilize simple VLF filters with no gas tube backup. Additional features include: * Excellent broadband performance from DC through 3 GHz, compared to the narrow-band DC-blocked or stub designs. Typical dB loss: 0.1@ 1 GHz; 0.2@ 2 GHz; and 0.5@ 3 GHz. * Innovative impedance-compensated, through-line cavity design allows control voltages to pass through the devices, instead of the "wire-around" requirement of DC-blocked designs. This design allows "in-circuit" cable sweeps. * Innovative, fast-acting gas tube replaceable Arc-Plug® module can be removed and replaced in the field in about one minute with no tools required, and without having to remove the protector from the circuit. The "O" ring sealed knurled knob does the trick! * The Arc-Plug® module and connectors are "O" ring sealed for complete weatherproofing. * Effective performance. Due to the carefully designed reactance-compensated, through-line cavity and Arc-Plug® module placement, customer and government test approvals show that this design is as good as, or better than, DC-blocked designs. Lightning surges do lots of damage annually. Protect your equipment from surges with Alpha Delta F Connector Coaxial Surge Protectors from DX Engineering!
( 3 )
$79.99
Alpha Delta Model LT Coaxial Surge Protectors
Alpha Delta Model LT Coaxial Surge Protectors provide lightning surge protection for transceivers on frequencies from DC up to 30 megahertz. Each unit features SO-239 UHF female connectors on both input and output. Every spring and summer, many pieces of amateur radio equipment are damaged beyond repair by lightning-induced voltage surges. An inexpensive investment in these Alpha Delta Model LT Coaxial Surge Protectors may be your best insurance to protect expensive HF equipment from destructive surge voltages! Don't sit by and allow surge damage. Order Alpha Delta Model LT Coaxial Surge Protectors from DX Engineering to put a damper on those surges!
( 2 )
$39.99
Alpha Delta Coaxial Switch Replacement Arc-Plugs®
Alpha Delta Coaxial Switch Replacement Arc-Plugs® are designed to reduce the hazards of lightning-induced or other high-voltage induced surges. When hit with a surge, they will short to ground, protecting your equipment, and will remain shorted and must be removed or replaced in order to continue operation. As with all lightning protection; these surge plugs will not prevent fire or damage caused by a direct lightning strike to an antenna, power lines, or other structure. Alpha Delta D4 Coaxial Switch Replacement Arc-Plugs® are direct replacements for Alpha Delta Coaxial Switch model Delta-2 and Delta-4 series switches. As when used in Alpha Delta Coaxial Switches, D4 Replacement Arc-Plugs® are rated at 1,500 watts CW and SSB PEP, ICAS, at an SWR under 2:1. Lightning surges do lots of damage annually. Don't let your sensitive Amateur Radio gear go unprotected. Order Alpha Delta Coaxial Switch Replacement Arc-Plugs® from DX Engineering!
( 13 )
$21.99